Z900
Programing Instructions..

--- Installer Level Programing Example ---

Press "9" - (installer code) - (function code) - # - (new value) - * - system returns to normal.

01. Press "9" and HOLD for three seconds. (three beeps)

02. Enter the Installer Program Code. (96321 at default) All LED's flash.

03. Enter the desired Function number (1-3 digits).
     The current Function value will be displayed through the LED's.
04. Press #. (two beeps)
     The value of the selected Function will be displayed through the LED's.

05. Enter the new value. Possible entries vary for different Functions.

06. Press *. (two beeps)
     The new value is now stored in the EEPROM.
07. Press # to step to the next Location,
     or enter a new Function number followed by this key # to the selected Function.
08. Press the * key twice to exit the programing mode.

--- Program Function Map ---

--- USER level programing ---
(use the Master user code to access)

((User authorization codes. Use any four digits (0-9). Digits may repeat.))
001 _ _ _ _ MASTER user authorization code (default is 1245)
002 _ _ _ _ user code 2 (default is none)
003 _ _ _ _ user code 3 (default is none)
004 _ _ _ _ user code 4 (default is none)
005 _ _ _ _ user code 5 (default is none)
006 _ _ _ _ user code 6 (default is none)

((Counters, Timers, and special use functions))
007 ___ Usage count for user code 6 (1-254, 255=permanent)(default is 255)
008 ___ Time until next communicator test (0-24 hrs)
009 ___ Clear alarm memory (no value required)
010 ___ Delete codes (1-6, 0 will delete the installer code)
011 ___ Entrance 1 Time in Seconds (1-255 seconds)(default is 30)
012 ___ Entrance 2 Time in Seconds (1-255 seconds)(default is 46)
013 ___ Exit Time in Seconds (1-255 seconds)(default is 60)
014 ___ Access Time in Seconds (0-255, 0= latch)(default is 5)
015 ___ Delay Burglar output in seconds (0-255)(default is 0)
016 ___ Burglar Cutoff time in minutes (1-254, 255=never cutoff)(default is 10)
017 ___ Aux "A" cutoff time in minutes (1-254, 255=never cutoff)(default is 255)
018 ___ Aux "B" cutoff time in minutes (1-254, 255=never cutoff)(default is 10)
019 ___ Aux "C" cutoff time in minutes (1-254, 255=never cutoff)(default is 10)
020 ___ Time between communicator test (0-7, 0=12 hrs, 1-7= 1 to 7 days)(default is 1)
021-032 Exits to programing entry
032 Begin upload data (no value required)(REMOTE programing mode)

--- Installer level programing ---
(use the Installer code to access)

((Configuration Digits for users codes 1-6))
034 ___ code 1 (default is 3)
035 ___ code 2 (default is 3)
036 ___ code 3 (default is 3)
037 ___ code 4 (default is 3)
038 ___ code 5 (default is 3)
039 ___ code 6 (default is 3)
040 Exits to programing entry mode

((Zone definitions (1-255) ))
((Refer to zone planing guide))
041 ___ zone 1 (default is 64)
042 ___ zone 2 (default is 72)
043 ___ zone 3 (default is 81)
044 ___ zone 4 (default is 65)
045 ___ zone 5 (default is 65)
046 ___ zone 6 (default is 65)

((Digital Communicator Setup))
047 ___ Communicator disable/delay in seconds (0-255, 0=disabled)(default is 0)
048 ___ Dial attempts before shutdown telephone # 1 (1-15)(default is 8)
049 ___ Dial attempts before shutdown telephone # 2 (1-15)(default is 8)
((note; odd value 1, 3, etc... will disable the fail to communicate warning)
((U.L. requires 5 dial attempts minimum, 10 maximum. An even value shall be selected to insure the Failed to communicate warning.))
050 ___ Dual reporting of alarms (0=No, 1=Yes)(default is 0)
051 ___ Dual reporting of Non-alarms (0=No, 1=Yes)(default is 0)
052 ___ Communicator on-hook time in seconds (0-255)(default is 3)
053 ___ Time between dial attempts is seconds (0-15)(default is 10)
054 ___ Abort communicator upon disarming (0=No, 1=Yes)(default is 0)
055 ___ Disable dialer test on powerup (0=No, 1=Yes)(default is 0)
056 ___ Exception opening/system restore (0=No, 1=Yes)(default is 0)

((Account number telephone # 1 (0-15) ))
057 ___ Digit 1 (default is 0)
058 ___ Digit 2 (default is 8)
059 ___ Digit 3 (default is 8)
060 ___ Digit 4 (default is 8)
((note; Digit 1 MUST always be "0" unless 4/2 format is enabled (function 63). A "0" signifies no entry. To report the number "0", a "10" must be programed. Some receivers translate numbers 10,11,12,13,14,15 to hexidecimal characters A,B,C,D,E,F respectively.))

((Reporting formats for Telephone # 1 (0-15) ))
061 ___ Transmission format (0-7)(default is 2)
062 ___ Single round report (0=No, 1=Yes)(default is 0)
063 ___ 4/2 transmission format (0=No, 1=Yes)(default is 0)
064 ___ Extended standard (0=No, 1=Yes)(default is 0)
065 ___ Extended single line (0=No, 1=Yes)(default is 0)
066 ___ Parity Checksum (0=No, 1=Yes)(default is 0)
067 ___ Touchtone dialing (0=No, 1=Yes)(default is 0)

((Reporting codes Telephone # 1 (0-15) ))
068 ___ zone 1 (default is 3)
069 ___ zone 2 (default is 3)
070 ___ zone 3 (default is 3)
071 ___ zone 4 (default is 3)
072 ___ zone 5 (default is 3)
073 ___ zone 6 (default is 3)
074 ___ KP panic "A" (default is 1)
075 ___ KP panic "B" (default is 2)
076 ___ KP panic "C" (default is 4)
077 ___ Duress (default is 0)
078 ___ Opening (disarmed)(default is 0)
079 ___ Closing (armed)(default is 0)
080 ___ Shunted zone (bypassed zone)(default is 0)
081 ___ Cancel (default is 0)
082 ___ Zone restore (default is 0)
083 ___ Supervisory/Trouble (default is 0)
084 ___ Low Battery (default is 0)
085 ___ Battery restore (default is 0)
086 ___ AC Failure (default is 0)
087 ___ AC restore (default is 0)
088 ___ Memory Error (default is 0)
089 ___ Auto test (default is 0)

((Number to dial Telephone # 1 (0-15)(defaults are all 15) ))
090 ___ Digit 1
091 ___ Digit 2
092 ___ Digit 3
093 ___ Digit 4
094 ___ Digit 5
095 ___ Digit 6
096 ___ Digit 7
097 ___ Digit 8
098 ___ Digit 9
099 ___ Digit 10
100 ___ Digit 11
101 ___ Digit 12
102 ___ Digit 13
103 ___ Digit 14
104 ___ Digit 15
105 ___ Digit 16
((note, A 0 or 10 = dialing number "0", 11 = "*" and 12 = "#", 13 = three second dialing pause, 14 = additional wait for dial tone, 15 = end of dialing and MUST be programed after the last valid number.. ))

((Special functions))
106 ___ Audio listen-in capability telephone # 1 (0=No, 1=Yes)(default is 0)
107 ___ Exit to programing entry mode
108 ___ Copy Telephone # 1, account, format and reporting codes to Telephpne # 2
109 ___ Copy Telephone # 1, Dialed number to Telephone # 2
- - - - - - - -

((Account number telephone # 2 (0-15) ))
110 ___ Digit 1 (default is 0)
111 ___ Digit 2 (default is 8)
112 ___ Digit 3 (default is 8)
113 ___ Digit 4 (default is 8)
((note; Digit 1 MUST always be "0" unless 4/2 format is enabled (function 63). A "0" signifies no entry. To report the number "0", a "10" must be programed. Some receivers translate numbers 10,11,12,13,14,15 to hexidecimal characters A,B,C,D,E,F respectively.))

((Reporting formats for Telephone # 2 (0-15) ))
114 ___ Transmission format (0-7)(default is 2)
115 ___ Single round report (0=No, 1=Yes)(default is 0)
116 ___ 4/2 transmission format (0=No, 1=Yes)(default is 0)
117 ___ Extended standard (0=No, 1=Yes)(default is 0)
118 ___ Extended single line (0=No, 1=Yes)(default is 0)
119 ___ Parity Checksum (0=No, 1=Yes)(default is 0)
120 ___ Touchtone dialing (0=No, 1=Yes)(default is 0)

((Reporting codes Telephone # 2 (0-15) ))
121 ___ zone 1 (default is 3)
122 ___ zone 2 (default is 3)
123 ___ zone 3 (default is 3)
124 ___ zone 4 (default is 3)
125 ___ zone 5 (default is 3)
126 ___ zone 6 (default is 3)
127 ___ KP panic "A" (default is 1)
128 ___ KP panic "B" (default is 2)
129 ___ KP panic "C" (default is 4)
130 ___ Duress (default is 0)
131 ___ Opening (disarmed)(default is 0)
132 ___ Closing (armed)(default is 0)
133 ___ Shunted zone (bypassed zone)(default is 0)
134 ___ Cancel (default is 0)
135 ___ Zone restore (default is 0)
136 ___ Supervisory/Trouble (default is 0)
137 ___ Low Battery (default is 0)
138 ___ Battery restore (default is 0)
139 ___ AC Failure (default is 0)
140 ___ AC restore (default is 0)
141 ___ Memory Error (default is 0)
142 ___ Auto test (default is 0)

((Number to dial Telephone # 2 (0-15)(defaults are all 15) ))
143 ___ Digit 1
144 ___ Digit 2
145 ___ Digit 3
146 ___ Digit 4
147 ___ Digit 5
148 ___ Digit 6
149 ___ Digit 7
150 ___ Digit 8
151 ___ Digit 9
152 ___ Digit 10
153 ___ Digit 11
154 ___ Digit 12
155 ___ Digit 13
156 ___ Digit 14
157 ___ Digit 15
158 ___ Digit 16
((note, A 0 or 10 = dialing number "0", 11 = "*" and 12 = "#", 13 = three second dialing pause, 14 = additional wait for dial tone, 15 = end of dialing and MUST be programed after the last valid number.. ))

((Special functions))
159 ___ Audio listen-in capability telephone # 2 (0=No, 1=Yes)(default is 0)
160 ___ Exit to programing entry mode

((Upload/Download callback telephone number to dial (0-15)(defaults are (15) ))
161 ___ Digit 1
162 ___ Digit 2
163 ___ Digit 3
164 ___ Digit 4
165 ___ Digit 5
166 ___ Digit 6
167 ___ Digit 7
168 ___ Digit 8
169 ___ Digit 9
170 ___ Digit 10
171 ___ Digit 11
172 ___ Digit 12
173 ___ Digit 13
174 ___ Digit 14
175 ___ Digit 15
176 ___ Digit 16
((note, A 0 or 10 = dialing number "0", 11 = "*" and 12 = "#", 13 = three second dialing pause, 14 = additional wait for dial tone, 15 = end of dialing and MUST be programed after the last valid number.. ))

((Control Options All except # 181 are 0=No, 1=Yes format, all defaulted to 0 except # 183 is 1))
177 ___ Two digit arming
178 ___ Enable force arming
179 ___ Permanent force arming (shunt)
180 ___ Delay burglar restore untill cutoff
181 ___ Burglar alarm report until lockout (0-15, 0=No communicator lockout)
182 ___ Pulsing Burglar alarm output
183 ___ Pulsing Auxiliary "A" (fire) output
184 ___ Burglar loop audible lockout
185 ___ Keyswitch mode change
186 ___ Supervisor/Day alert latch
187 ___ Automatic interior off
188 ___ Extended Burglar alarm loop stabilization
189 ___ Disable interior follower
190 ___ Interior on/off available if armed
191 ___ Delay off when interior off
192 ___ Siren/bell test upon arming
193 ___ Reset test timer on kissoff
194 ___ Interior default upon disarm

((Control Station Options (0=No, 1=Yes)(default is all 0 except for 198 is 1) ))
195 ___ Disable keypad shunting
196 ___ Disable key 4 interior on/off
197 ___ Disable key 6 chime on/off
198 ___ Disable key 7 power interrupt
199 ___ Disable key 8 walk test
200 ___ Silent keypad on burglar alarm
201 ___ Silent keypad/no leds blinking on Aux "B" alarm
202 ___ Start entrance delay 1 on keypad entries

((Zone Supervisiory, (Trouble upon; 0=Open, 1=Short) ))
203 ___ zone 1 (default is 0)
204 ___ zone 2 (default is 0)
205 ___ zone 3 (default is 0)
206 ___ zone 4 (default is 0)
207 ___ zone 5 (default is 0)
208 ___ zone 6 (default is 0)

((Extended Report Digits, (0-15) ))
((User codes 1-6))
209 ___ code 1 (default is 1)
210 ___ code 2 (default is 2)
211 ___ code 3 (default is 3)
212 ___ code 4 (default is 4)
213 ___ code 5 (default is 5)
214 ___ code 6 (default is 6)
215 ___ Extended keyswitch zone reporting code (default is 7)

((Zone Alarms 1-6))
216 ___ zone 1 (default is 1)
217 ___ zone 2 (default is 2)
218 ___ zone 3 (default is 3)
219 ___ zone 4 (default is 4)
220 ___ zone 5 (default is 5)
221 ___ zone 6 (default is 6)

((Zone restorals 1-6))
222 ___ zone 1 (default is 1)
223 ___ zone 2 (default is 2)
224 ___ zone 3 (default is 3)
225 ___ zone 4 (default is 4)
226 ___ zone 5 (default is 5)
227 ___ zone 6 (default is 6)

((Zone shunts 1-6))
228 ___ zone 1 (default is 1)
229 ___ zone 2 (default is 2)
230 ___ zone 3 (default is 3)
231 ___ zone 4 (default is 4)
232 ___ zone 5 (default is 5)
233 ___ zone 6 (default is 6)

((Zone Supervisory/Trouble 1-6))
234 ___ zone 1 (default is 1)
235 ___ zone 2 (default is 2)
236 ___ zone 3 (default is 3)
237 ___ zone 4 (default is 4)
238 ___ zone 5 (default is 5)
239 ___ zone 6 (default is 6)

((Misc. Extended Reporting Digits))
240 ___ Extended AC code (default is 10)
241 ___ Extended Battery code (default is 9)
242 ___ Extended Memory error code (default is 15)
243 ___ Extended Test code (default is 9)
244 ___ Extended keypad panis "A" code (default is 9)
245 ___ Extended keypad panis "B" code (default is 9)
246 ___ Extended keypad panis "C" code (default is 9)
247 ___ Extended missing keypad code (default is 15)

((Special purpose all are Yes/No format (except 251,252,255,256,264 & 269) ))
248 ___ Eliminate Burglar zone EOLR Supervision (default is 0)
249 ___ Exit to programing entry mode
250 ___ Restore user code 1 default value (no value required)
251 ___ Fast loop response time (0-15)(default is 2)
252 ___ Slow loop response time (0-15)(default is 6)
253 ___ Exit to programing entry mode
254 ___ Restore factory defaults (1=Yes)
255 _ _ _ _ _ _ Installer program authorization code (default is 96321)
256 ___ Assignable output (term # 3) definition (0-4)(default is 0)
257 ___ Burglar alarm activates assignable output (term # 3)(default is 1)
258 ___ Aux "A" (fire) alarm activates assignable output (term # 3)(default is 1)
259 ___ Aux "B" (police) alarm activates assignable output (term # 3)(default is 1)
260 ___ Aux "C" (emergency) alarm activates assignable output (term # 3)(default is 1)
261 ___ Disable keypad panic Aux "A"(fire)(default is 0)
262 ___ Disable keypad panic Aux "B"(police)(default is 0)
263 ___ Disable keypad panic Aux "C"(emergency)(default is 0)
264 ___ Factory use not programable
265 ___ Factory use not programable
266 ___ Factory use not programable
267 ___ Telephone # 1 upload/download complete reporting code (default is 9)
268 ___ Telephone # 2 upload/download complete reporting code (default is 9)
269 ___ Extended upload/download completed reporting code (default is 9)
270 ___ Dial tone detection/1 alarm per zone until disarm (default is 0)
271 ___ Keypad panic 3 second (hold or press twice) mode(0=instant, 1=3 sec.)(default is 1)
272 ___ Answer machine bypass 2nd call time limit (10 seconds increments)(0-15)(default is 0)
273 ___ Listen-in time (1-15)(default is 1)

--- Restoring the factory default program ---

01. Enter the installer level programing mode by following steps 1 and 2 above. (If the code is unknown, press and hold keys "3" and "9" simultaneously for three seconds within 60 seconds of control powerup). The control station LED's will flash indicating entry into the programing mode.
02. Enter Function 254 and press the "#" (FIND) key.
03. Enter a value of "1" and press the "*" (STORE) key. The first LED (zone 1) should now be lighted.
04. Press the "*" (STORE) key twice to exit the programing mode. There will be a 5-10 second delay while the control restores the factory default values. During this time the control will not respond to other commands. After approximately 5-10 seconds, the factory default values will be restored and the control will return to normal operations.